Representations and normalization
In the common preparation, reducing a spherically symmetric problem makes its radial equation easier to solve. When you move to FLODI, the same physical state is represented by a physical field, so the stored values and their integration measure change together. Establishing that connection before applying an operator helps you understand apparent differences in arrays or normalization without treating them as unexplained numerical factors.
From the assignment’s radial function to a physical field
The common preparation uses the reduced radial function \(u=rR\). For a spherically symmetric orbital,
These definitions describe the same orbital, so each representation must assign it the same physical norm. Substituting the definitions into the three-dimensional integral makes the required measures explicit:
Stored quantity |
Meaning |
Normalization measure |
|---|---|---|
\(\psi\) |
Physical spatial orbital, including its angular normalization |
\(\mathrm d^3r\) |
\(R\) |
Radial factor with a normalized angular factor separated out |
\(r^2\,\mathrm dr\) |
\(u=rR\) |
Reduced radial function from the common preparation |
\(\mathrm dr\) |
$p= |
u |
^2$ |
\(n\) |
Total electron density per physical volume |
\(\mathrm d^3r\), giving the electron count |
FLODI’s orbital interfaces use the first of these conventions: their
arguments are physical fields. On a radial grid, the shell volumes in
grid.integrate(psi.conj(), psi) supply the geometric weight needed for
that norm, while the Laplacian acts on \(\psi(r)\) with spherical geometry
included. The simpler second derivative of \(u\) belongs to the reduced
radial equation, so transferring that derivative directly to a physical
field would change the operation being evaluated.
When comparing your preparation code with FLODI, compare physical quantities such as norms or expectation values. The two discretizations use different sampling points and quadrature rules, so their arrays and finite-grid errors will generally differ even when they represent the same continuous function.
Cell centres and cell faces
The preparation’s endpoint grid and FLODI’s cell-centred grid have different
bookkeeping. A FLODI radial grid with n_r cells on \([0,R]\) has
Its first centre is positive, its last centre is inside the outer face, and its physical shell volumes are
This layout explains why FLODI distinguishes grid.r, which contains
the centre coordinates, from grid.r_faces, which contains the faces.
Likewise, psi.values[-1] samples the last centre inside the domain,
whereas psi.boundary describes the outer face beyond it. Setting that
face to zero still leaves the last centre as an unknown whose value need
not vanish. The boundary-conditions guide shows how to
supply face data for the operation you intend to perform.
What integration does
For physical fields, integration means
Each term combines the sampled integrand with the physical volume it
represents, and the volume enters only once regardless of the number of
arguments. Conjugation remains explicit because a general product integral
need not be an inner product; for the squared norm of a complex field,
write grid.integrate(f.conj(), f).
The volume weights also explain why an ordinary NumPy sum or Euclidean
array norm measures something different. np.sum(f.values) adds the
samples without accounting for their physical volumes, while
np.linalg.norm(f.values) uses those same unweighted samples in its norm.
Both can help with array debugging, but a physical field norm requires
the volume-weighted integral.
Reduced measures are a separate interface
grid.integrate_reduced supports explicitly separated angular factors.
On radial grids it integrates \(R\) with \(r^2\,\mathrm dr\). On prolate grids
it omits the azimuthal factor \(2\pi\) for a convention in which that factor
has been normalized separately. It does not implement the \(\mathrm dr\)
measure for \(u\), and full spherical grids have no reduced measure.
Use ordinary integrate for the physical orbital amplitudes expected by
lowest_orbital, lowest_orbitals, and closed_shell, including nonzero
prolate angular sectors. Choose the convention before sampling, rather than
correcting unexplained factors after a calculation.
Solver vectors carry volume weights
The eigensolver works with a vector \(y_\alpha=\sqrt{\Delta V_\alpha}\psi_\alpha\), so that
The conversion grid.to_vector implements this relation by applying the
weights and flattening the field, while grid.from_vector reverses it
without renormalizing. This gives the lower-level solver a Euclidean inner
product that agrees with the physical one. When using the high-level
eigensolvers, that conversion has already been handled and the returned
fields are physically normalized; you only need to work with the weights
explicitly when using the lower-level vector interface.
Electron density and source density
A Poisson source is a density per physical volume. Its interpretation comes from the equation you are implementing: it might be a one-electron density, a total density, or a signed orbital-product amplitude. FLODI applies the same linear Poisson operation to each.
To interpret a Poisson solve, first identify what its source means and
what integrating that source should measure. This physical counting is a
separate choice from normalizing an individual orbital. For example, an
occupied-state object’s state.density includes both spin occupations,
so its integral agrees with state.electron_count. Use the assignment’s
model to establish the electron and pair counting before translating its
equations into field operations.